21
GB
11. Repairs
Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty period
should only be carried out by skilled technical personnel. Failure to observe the assembly and
setting procedures and operation by non-skilled personnel may result in serious damage to the
riveting tool. In case of doubt, always send in the device to the manufacturer.
Regular maintenance will extend the service life of your high-quality GESIPA
®
tools and they should be serviced at least every 2 years by an authorised
workshop or by GESIPA
®
Service. For tools that are subject to intensive use,
we recommend servicing ahead of schedule.
12. Troubleshooting
12.1 Blind rivet is not set
Cause Remedy
Jaws (No. 4) dirty Clean and oil sliding surfaces (see 10.1)
Jaws (No. 4) worn Replace (see 10.1)
Insufcient compressed air See operating pressure (see 3.)
12.2 Spent mandrel is not conveyed automatically into the container
Cause Remedy
Wrong nosepiece used (No. 1) Replace according to table (see 6.)
Nosepiece (No. 1) worn Replace
Spent mandrel jammed in jaw housing
(No. 3)
Clean or replace jaw mechanism (see 10.1)
Spent mandrel container full Empty (see 9.)
Wrong jaw pusher (No. 5) used Replace according to table (see 6.) and
refer to Section 10.1