P Parameter Default
value
Lower
limit
Upper
limit
Unit Description
PF35 A0_VALUE 0 0 1 C Activate A0 control
0=Off
1=On
PF36 BGA (A+B) 0 0 1 - Activate BGA function
0=Off
1=On
PF37 START DRAIN 0 0 1 - Activate short draining at
beginning of program
0=Off
1=On
TI11 COOLING TIME 00:00:3
0
00:00:00 00:00:00 - Cooling down time after drying
TI17 DRAINING TIME 00:01:0
0
00:01:00 00:02:00 - Draining time between phases
TI18 FILL STEP 1 SING 00:01:0
0
00:00:00 00:03:00 - Fill time before pump starts
(machine without salt filter,
filling with a valve)
TI19 FILL STEP 2 SING 00:00:2
0
00:00:00 00:03:00 - Fill time at the same time as the
pump starts (machine without
salt filter, filling with a valve)
TI20 FILL STEP 1 SALT 00:02:2
0
- - - Fill time before pump starts
(machine with salt filter)
TI21 FILL STEP 2 SALT 00:00:3
0
- - - Fill time at the same time as
pump starts (machine with salt
filter)
TI22 FILL STEP 1 DOUB 00:00:3
0
00:00:00 00:03:00 - Fill time before pump starts
(machine without salt filter,
filling with two valves)
TI23 FILL STEP 2 DOUB 00:00:1
0
00:00:00 00:03:00 - Fill time at the same as the
pump starts (machine without
salt filter, filling with two valves)
TI42 START DRAIN 00:00:1
0
00:00:00 00:01:00 - Draining time in start phase
TI49 CONDENSER TIME 00:05:0
0
00:03:00 00:10:00 - Cooling time via condenser
before dryer fan starts
TI59 CHAMBER LIGHT
00:05:0
0
00:00:00 01:00:00 - Standby time for lighting
TI76 SLOW DOS 1 00:00:0
5
00:00:05 00:00:20 - Control time for
flow monitoring dosage 1
TI77 SLOW DOS 2 00:00:0
5
00:00:05 00:00:20 - Control time for
flow monitoring dosage 2
TI78 SLOW DOS 3 00:00:0
5
00:00:05 00:00:20 - Control time for
flow monitoring dosage 3
TI79 SLOW DOS 4 00:00:0
5
00:00:05 00:00:20 - Control time for
flow monitoring dosage 4
3 MENU TREE
48 (128) TECHNICAL MANUAL GETINGE WD15 CLARO