27
4
English
Programming
MENU 3
3.1 Operation mode
3 different operation modes are available, dening how the motor unit responds to OPEN
and CLOSE commands from 1- or 2-button controls.
Settings:
Mode 1 : Standard 2-button operation (default setting)
button press < 1s.: system moves to end postition
button press > 1s.: system moves for the duration of the connection or button press
Mode 2 : Inverted 2-button operation (‘vertical blinds’ setting)
button press < 3s.: system moves for the duration of the connection or button press
button press > 3s.: system moves to end postition
Note: recalling intermediate positions or programming end positions for the rst time is not
possible when mode 2 is active.
Mode 3 : 1-button operation
button press < 1s. : system closes, opens or stops
1. When the system is in one of its end positions:
- > move to opposite end position.
2. When the system is moving:
- > STOP
3. After a stop, press button again within 2s:
- > move in opposite direction
4. After a stop, press button again after 2s:
- > continue in same direction
Note: recalling intermediate positions is not possible when this feature setting is active.
After 15s. without input, the motor unit quits programming mode.
Please read the steps of this feature rst before starting.
SET Operation mode
motor LED colour red:
1. Press and hold the OPEN+CLOSE buttons until the LED on the motor unit ashes
white at high speed (after ~12s.)
(First the LED will turn white continuously, then ashes white slowly, keep pressed
until the LED ashes white at high speed)
2. Repeatedly press OPEN or CLOSE until the LED on the motor unit is red.
3. Shortly press the OPEN+CLOSE buttons to enter the feature menu,
4. The LED on the motor unit now ashes red at the current setting:
5. Cycle through the options below using OPEN or CLOSE:
1x ash = Standard 2-button operation (Default)