34
B3
English
Programmeer principes (En)
Basic principles for programming
Enter Programming mode
1. Enter Programming menu’s by pressing both OPEN
+
CLOSE:
release after 4 [s] for menu 1, when LED switches on (white)
release after 8 [s] for menu 2, when LED blinks slowly (white)
release after 12 [s] for menu 3, when LED blinks fast (white)
Making changes
2.
Within the menu, cycle forward or backwards through the coloured features
using
OPEN
or
CLOSE button.
Only available options (colours) will be shown.
3.
To enter the desired feature, shortly press both
OPEN
+
CLOSE:
coloured LED starts ashing:
3.A
The number of ashes shows the current feature-setting.
Cycle forward or backwards through the settings using
OPEN
or
CLOSE.
Each setting is represented by a certain ash count.
or
3.B
The unit is ready to communicate with a secondary device, like Remote Con-
trol to set channels or to pair with Bluetooth.
- When data is received and stored the LED is ON GREEN shortly;
- When previous data is deleted the LED is ON RED shortly;
The LED starts blinking again in order to process new information.
4.
Conrm feature-setting by shortly pressing both
OPEN
+
CLOSE
(< 2 [s])
Program returns to previous white menu.
Switch between Programming menus 1, 2 and 3
5.
At any moment during programming, press and hold both
OPEN
+
CLOSE
:
release after 4 [s]
: current Programming menu (white LED);
release per 4 [s] interval : next Programming menu appears (white LED).
A round-robin approach is used: after Programming menu 3, Programming
menu 1 is reached again.
Quit Programming
6.
To quit programming menus 1, 2 and 3 without entering a feature menu:
- press both
OPEN
+
CLOSE
shortly or
- wait for >15 [s]
To quit programming from within the feature menu (no changes):
- wait for >15 [s]
7.
When the user does not press a button > 15 [s] AND no changes are made
and stored, the unit quits programming without any changes.
The User mode is activated.