29
Step3: Create PV Station
Fill in the table of the “New Station” web page according to
the actual location of your PV station. In the
“EzLogger/EzMonitor Information” column, type the
information of your EzLogger, including S/N and Check Code.
Then click “Add” button. Type the information of your
inverter such as S/N, Check Code, Type and Description and
click “Add” button. If you got several non-WIFI type inverters
for single PV station, you need to type the information of
inverter one by one.
NOTICE: ONLY THE DATA FROM INVERTER WITH THOSE
INFORMATION ENTERED CORRECTLY IN THE WEBSITE CAN BE
VIEWED.
3.4.6 Communication with Solar-Log Device
All GoodWe inverters can be monitored by Solar-
Log200/500/1000.
Work steps
• Switch off the inverters and Solar-Log;
• Follow the steps in 3.4.3 connection procedure to install the
RS485 interface in the inverters;
• Connect inverters to the Solar-Log;
• Connect the inverters to each other;