Technical Data GW100K-HT GW110K-HT GW120K-HT GW136K-HTH
Cooling Method Smart Fan Cooling
Display LED, LCD (Optional) , WLAN+APP
Communication protocols modbus-RTU (SunSpec compliant)
Communication RS485, WiFi or 4G(Optional)
RS485, WiFi
or 4G or PLC
(Optional)
Weight (Kg) 93.5 98.5 98.5 98.5
Dimension (W×H×Dmm) 1008× 678× 343
Noise Emission (dB)
*3
< 80
Topology Non-isolated
Self-consumption at Night (W) < 2
Ingress Protection Rating IP66
Anti-corrosion Class C5 (Optional)
DC Connector MC4 (4~6mm²)
AC Connector OT/DT terminal (Max. 300mm²)
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DCII / ACIII
Protective Class I
The Decisive Voltage Class (DVC)
PV: C
AC: C
com: A
Active Anti-islanding Method AQDPF+AFDPF
Country of Manufacture China
NOTE:
*1: For Australia is 99.99kW/kVA
*2: For Brazil Nominal Output Voltage (V): 380, 3L/N/PE or 3L/PE
*3: For Korea Noise Emission(dB): < 70
*4: For Belgium Max. AC Active Power (kW), GW100K-HT is 100, GW110K-HT is 110, GW120K-HT is
120, GW136K-HTH is 136.
*5: For Belgium Max. AC Apparent Power (kVA), GW100K-HT is 100, GW110K-HT is 110, GW120K-
HT is 120, GW136K-HTH is 136.