Troubleshooting
Error Error
Error
Codes Codes
Codes
Online Online
Online
Troubleshooting Troubleshooting
Troubleshooting
Seehelp.graco.comformoredetailontroubleshootingerrors.
NOTE: NOTE:
NOTE:
Whenanerroroccurs,besuretodeterminethecodebeforeresettingit.Ifyouforgetwhicherrorcode
occurred,seetheErrorsscreentoviewthelast200errors,includingdate,time,anddescription.
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
HoseResistance
Modeisselected
andTCMhasbeen
replacedwithout
re-calibration.
Re-calibratethehose.Followthe
CalibrationProcedure,page72.
05CH
ADM/
TCM
Hose
re-calibration
recommended
HoseResistance
Modeisselected
andADMhasbeen
movedtoanew
systemwithout
re-calibration.
Re-calibratethehose.Followthe
CalibrationProcedure,page72.
Fluidnotinsystem.
No󰘱uidinthepumpcancausealow
motorcurrenterror.Verify:
Fluidisinpumps.
Inletvalvesareopen.
Systemcannot
buildpressure.
Anoutletrestrictiondoesnotexist.
VerifyreliefvalvesareinSPRAY
position.
Loose/broken
connection.
Verify:
Powerconnectoristightlyconnected
atMCMport#15.Con󰘰rmwiringis
notpullingconnectoroutofproper
position.
Cableinsulationorwireisnotcut
orfrayed.
Wiresaretightlytorquedinpower
connectorterminals.Testby
pullingonindividualwiresinpower
connector.
Cablenotdamagedatstrainrelief
onmotorcase.
A1NM
MCM
LowMotor
Current
Badmotor.Disconnectmotorpowerconnectorat
MCMport#15.Measureresistances
atmotorpowerconnector.
Mustreadlessthan8ohmsresistance
betweeneachpairofmotorpower
leads(M1toM2,M1toM3,M2toM3).
Ifanyreadingsgreaterthan8ohms
andpreviousstep("Loose/broken
powerconnectionormotorcable")
wasveri󰘰ed,thenmotormayneed
replacement.