Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Inletpressurelower
thandenedvalue.
Ensurethatinletpressuretothepump
issufcient.
P2FA
MCM
LowInlet
PressureA
Valuedenedtoo
high.
Ensurethatthelowpressurealarm
leveldenedontheSystemSetup
screenisacceptable.
Inletpressurelower
thandenedvalue.
Ensurethatinletpressuretothepump
issufcient.
P2FB
MCM
LowInlet
PressureB
Valuedenedtoo
high.
Ensurethatthelowpressurealarm
leveldenedontheSystemSetup
screenisacceptable.
System
pressurizedbefore
allowingheatto
reachsetpoint.
Pressureinthehoseandpumpswill
increaseasthesystemheatsup.
Turnonheatandallowallzonesto
reachthetemperaturesetpointbefore
turningonthepumps.
Badpressure
transducer.
VerifytheADMpressurereadingand
theanaloggaugesatthemanifold.
P4AX
MCM
HighPressure
A
E-XP2system
conguredasE-30.
AlarmlevelislowerforE-30thanfor
E-XP2.EnsuredialonMCMissetto
position"3"forE-XP2.
System
pressurizedbefore
allowingheatto
reachsetpoint.
Pressureinthehoseandpumpswill
increaseasthesystemheatsup.
Turnonheatandallowallzonesto
reachthetemperaturesetpointbefore
turningonthepumps.
Badpressure
transducer.
VerifytheADMpressurereadingand
theanaloggaugesatthemanifold.
P4BX
MCM
HighPressure
B
E-XP2system
conguredasE-30.
AlarmlevelislowerforE-30thanfor
E-XP2.EnsuredialonMCMissetto
position"3"forE-XP2.
TheA-side(ISO)
pumpinletballor
seatisdamaged.
ReplacetheA-side(ISO)pumpinlet
ballandseat.
P4FAADMHighInlet
Pressure
(A-side)
TheA-side
(ISO)material
isexpanding
betweenthe
materialdrumand
theproportioner.
Toavoidthermalexpansion,condition
theA-side(ISO)materialdrumtothe
sameambienttemperatureasthe
proportioner.
TheB-side(RES)
pumpinletballor
seatisdamaged.
ReplacetheB-side(RES)pumpinlet
ballandseat.
P4FBADMHighInlet
Pressure
(B-side)
TheB-side
(RES)material
isexpanding
betweenthe
materialdrumand
theproportioner.
Toavoidthermalexpansion,condition
theB-side(RES)materialdrumto
thesameambienttemperatureasthe
proportioner.