Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Fluidisoverheated
inportionsofhose
exposedtoan
excessiveheat
source,likehot
directsunlight.
Whenspraying
begins,overheated
uidpassesover
theFTS,triggering
thisalarm.Trigger
pointis27°F
(15°C)over
hosetemperature
setting.
Shadeexposedhosefromhotsun
orexposeFTStosameenvironment
whenatrest.
Coiledhose
createsexcessive
heatinaportion
ofthehose.When
sprayingbegins,
theoverheated
uidpassesover
theFTS.
Uncoilentirehosebeforeheating.
Multiplesectionsofhosepiledor
wrappedcreatesself-heatingand
leadstothisproblem.
T4DHHoseHigh
Temperature
Hose
Fluidhose
insulationmissing
fromoverFTS,
leadingtoerratic
hosetemperature
control.
Hosetemperatureismeasuredinthe
A-side(red)uidhoseapproximately
18in.(0.5m)backtowardthe
proportionerfromtheFTSttings.
Conrmthatinsulationisintactover,
atminimum,thelast6ft(2m)ofthe
A-sidehose.Ifnot,replacemissing
insulationovertheindividualhoses.
(Wrappingreplacementinsulationover
thewholehosebundleisnotsufcient
forproperhosetemperaturecontrol.)
Replacementinsulationisavailable
fromGracoorahardwarestore.
SettingtheAor
Bsetpointmuch
higherthanhose
setpointcancause
uidmorethan27°
F(15°C)overhose
temperaturesetting
toreachtheFTS.
Increasehosesetpointsoitiscloser
toAandBsetpoints.
T4DHHoseHigh
Temperature
Hose
Coldambient
temperatureis
causinghoseto
heat.
Coldambienttemperatureischilling
theFTSandcausinghoseheattostay
onlongerthanneeded.Insulatethe
FTSareaofthehosesothatitheatsat
thesamerateastherestofthehose.
333024S 31