16 3A1570V
Shutdown
1. Turn main heater power OFF .
2. Follow Park.
3. Check and fill wet-cups (AK, Z).
4. Follow gun shutdown procedure. See gun manual.
Park
Park the pumps at the end of the day to cycle
component A pump to home position, submerging
displacement rod.
1. Open the park valve.
2. Trigger the gun until pumps stops at the bottom and
relieves pressure.
3. Close the air motor shutoff valve.
4. Close the park valve.
Z
ti16974a
AK
Close
Open