Repair
3A1570V 41
Replace DataTrak Battery or Fuse
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
IG
. 18.
2. Remove the cable from the two cable clips.
3. Remove DataTrak module from bracket. See F
IG
.
19. Take module and attached cable to a
non-hazardous location.
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See F
IG
. 20.
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement
batteries. Use of an unapproved battery will void
Graco’s warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse.
Order Part 24C580.