Repair
28 3A1570V
Air Inlet Filter / Water Separator
(Auto Drain)
Air Filter Element Removal
1. Close air inlet valve (302) on filter (301).
2. Hold in metal spring clip and twist black cover
counterclockwise to remove.
3. Unscrew clear drain cover by hand.
4. Unscrew black filter element retainer to remove
element.
5. Inspect filter element. Clean or replace.
Air Filter Element Installation
1. Insert cleaned or replacement filter (15D909).
2. Hand-screw filter retainer into place.
3. Hand-screw clear drain cover until tight.
4. Reposition black cover and turn. Make sure it
“snaps” back into place.
F
IG
. 5
302 301
ti17996a