Default value is 97. Defines payload type for iLBC. The valid range is between
96 and 127.
AAL2-G726-16
Payload type
Default value is 100. Range is from 96 to 127.
AAL2-G726-24
Payload type
Default value is 99. Range is from 96 to 127.
AAL2-G726-32
Payload type
Default value is 104. Range is from 96 to 127.
AAL2-G726-40
Payload type
Default value is 103. Range is from 96 to 127.
Default value is 102. Range is from 96 to 127.
Default is No. VAD allows detecting the absence of audio and conserve
bandwidth by preventing the transmission of "silent packets" over the network.
Default is No. When set to Yes the device will change the destination to send
RTP packets to the source IP address and port of the inbound RTP packet last
received by the device.
T.38 (Auto Detect) FoIP by default, or Pass-Through (must use codec
PCMU/PCMA)
Default is Callee. This decides whether Caller or Callee sends out the re-INVITE
for T.38 or Fax Pass Through.
Select either Fixed or Adaptive based on network conditions.