CE5000-UM-251-9370 6-24
6 DISASSEMBLY AND REASSEMBLY
6.2.11 How to Replace the Y-motor
How to detach the Y-motor
(1) Detach the right side cover (see Subsection 6.1.1).
(2) Detach the front guide (see Subsection 6.1.5 or6.1.6).
(3) DisconnecttheY-motorcablesfromconnectorJ8andJ11onthemainboard.
(4) LoosenthetwoM3L4WPsetscrewstodetachtheY-motorpulley.
M3L4WP set screw
Y-motor pulley
Y-motor drive belt
M3L6 binding head screw
Y-motor
(5) RemovethethreeM3L6bindingheadscrewsholdingtheY-motor.
(6) DetachtheY-motorpulley,thendetachtheY-motor.
(7) DetachthepulleyangeandthespacerfromtheY-motor.
Y-motor
Spacer
Pulley flange