CE5000-UM-251-9370 7-1
7 ELECTRICAL ADJUSTMENTS
7 ELECTRICAL ADJUSTMENTS
7.1 DIP Switch Settings
Factory presets (Normal Mode)
For old type of main board:
Set all the bits to OFF.
SW1
1234
ON
OFF
For new type of main board:
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF OFF CE5000-40CRP (Craft ROBO Pro)
SW1
1234
ON
OFF
ON OFF OFF OFF CE5000-60
SW1
1234
ON
OFF
OFF ON OFF OFF CE5000-120
SW1
1234
ON
OFF
ON ON OFF OFF CE5000-120AP
NOV-RAM Clear
For old type of main board:
Set bit 3 to ON.
SW1
1234
ON
OFF
For new type of main board:
Dip Switch 1 2 3 4 Model
SW1
1234
ON
OFF
OFF OFF OFF ON CE5000-40CRP (Craft ROBO Pro)
SW1
1234
ON
OFF
ON OFF OFF ON CE5000-60
SW1
1234
ON
OFF
OFF ON OFF ON CE5000-120
SW1
1234
ON
OFF
ON ON OFF ON CE5000-120AP