CE5000-UM-251-9370 7-6
7 ELECTRICAL ADJUSTMENTS
(12) Adjustthe450g-penforce.Ifthemeasuredvalueiswithinthespecicationrange(450±20g)orifyou
have input the recorded value, press the ENTER key to store the setting. (Only for the CE5000-120.)
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changesthetemperatureoftheactuatorandcausesarticiallylowerreadings.Whenthishappensthe
actualpenforcemaybehigherthanthespecication.Thisisespeciallytruefortheupperpenforce
adjustment.
(13) Press the NEXT key to complete this adjustment.
Specication of the actual pen force
Speciedpenforce Actual force range Remark
10 g 8 to 12 g
40 g 36 to 44 g
120 g 110 to 130 g
300 g 280 to 320 g
450 g 430 to 470 g Only for the CE5000-120