CE5000-UM-251-9370 7-8
7 ELECTRICAL ADJUSTMENTS
(10) Press the ENTER key to store the setting. The following menu appears as like.
If you are not adjusted about the distance, L=500.00 appears. This is only displaying the calculated
value.
If you want to adjust the right-angled accuracy, measure the diagonal distance, and then input the
measured value to the L value by this menu.
XY LENG L=***.**
(11) YoumustpresstheENTERkeytodrawthetestpatternagain,andthenconrmthedistanceadjustment.
If you pressed the NEXT key at above menu, the adjustment value will not be stored.
(12) The following menu appears after the test pattern was drawn.
(The adjusted X and Y values are displayed at this menu.)
DADJ.X= 0 Y= 0
If you wish to complete this adjustment, press the NEXT key. If you wish to plot the adjusted test pattern,
press the ENTER key.