EasyManua.ls Logo

GRAPHTEC CE5000-60 - Error Messages in Gp-Gl Command Mode

GRAPHTEC CE5000-60
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 – 6
If any of the following command error messages appear, they are nearly always caused by one of the fol-
lowing two reasons:
The software or host-computer settings have been changed.
The cutting-plotter interface settings have been changed.
Solutions
Configure the settings in the software menu so that the menu can control the cutting plotter.
Set the host-computer interface conditions correctly.
Set the cutting-plotter interface conditions correctly (see “3.1 Setting the Format of Data to be
Received”).
Make sure that the data-transmission conditions match.
Error messages in GP-GL command mode
Error message Cause Solution
GP-GL ERROR 1 An unrecognizable command was received.
Noise was received when the computer was turned
on.
Press the ENTER key to cancel
the error.
The software command settings for controlling the
cutting plotter have been changed.
Set the software command set-
tings for controlling the cutting
plotter.
The data-transmission settings have been changed
in the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 2 The command terminator is incorrect.
The software settings for the output device have
been changed.
Set the software command set-
tings for controlling the cutting
plotter.
The data-transmission settings have been changed
in the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 3 The command delimiter is incorrect.
The software settings for the output device have
been changed.
Set the software command set-
tings for controlling the cutting
plotter.
The data-transmission settings have been changed
in the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 4 The command parameter exceeds the permissible
range.
The software settings for the output device have
been changed.
Set the software command set-
tings for controlling the cutting
plotter.
The data-transmission settings have been changed
in the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 5 An error occurred in the reception of data within the
interface.
The software command settings for controlling the
cutting plotter have been changed.
Set the software command set-
tings for controlling the cutting
plotter.
The data-transmission settings have been changed
in the interface settings.
Set the correct data-transmission
conditions.

Table of Contents

Other manuals for GRAPHTEC CE5000-60

Related product manuals