FC7000-UM-251-9370 7-11
7. ADJUSTMENT
7.3.4 Explanation of the Values of the Main Board Settings
(Default factory settings)
The default factory settings are recorded in the location shown below.
The default factory settings
are recorded here.
The contents of an example record are shown below.
25 47 100 228 346
X= 0 X= 80 X= -
Y= 4 Y= 50 Y= -
Explanation of the values
Pen force values
10 g 40g 120 g 300 g 450 g (400g)
Distance adjustment values Gain adjustment values Auto registration mark position adjustment values
X X X
Y Y Y
You can input the same values when you have replaced the main board without making any adjustments.