EasyManua.ls Logo

GRASS VALLEY JUPITER CM-4400 - VERSION 7.9.0 - 10-2010 - Page 42

GRASS VALLEY JUPITER CM-4400 - VERSION 7.9.0 - 10-2010
310 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42 JUPITER CM-4400 Control Module Installation and Operating Manual
Section 2 — Hardware Installation
Before configuring the Panels, you must have the following informa-
tion:
The IP address
•T
he Subnet
The Gateway (if located on another subnet, or being used across a
WAN)
The Unique Device ID
The IP address of the Primary and Secondary (Redundant) System
Controllers
Follow these steps to configure the AccuSwitch Control panels:
1. Start the NetConfig program and navigate to the AccuSwitch Control
panels using the Device View selection in the Navigation panel on the
left side of the NetConfig application.
a. You may not be able to browse to the panel if the current IP address
of the panel is not part of the Jupiter Subnet. NetConfig can be used
to set the IP address first if this is the case.
2. Select the Panel Network hyperlink. The Panel Network Configuration
page will then appear (Figure7).
Figure 7. Panel Network Configuration - IP Settings
3. Enter a unique IP address in the Ethernet IP field. This IP address should
be within the same network as the CM-4400.
For example, if the CM-4400 address is 10.16.91.10, the L-S or LCD
P
anels address should be changed to reside in the 10.16.91.xx network
(such as “10.16.91.210” as shown in Figure8).

Table of Contents