JUPITER CM-4400 Control Module Installation and Operating Manual 43
Connecting the CM-4400 to the Jupiter LAN
4. Enter 255.255.255.0 in the Subnet Mask field.
5. Enter a unique value in the Gateway field. See your network
administrator for this IP address.
Note If the L-S or LCD Panels and the CM-4400 are on separate networks, the
gateway connecting them must be specified.
Connection Type
Follow these steps to select the Connection type:
1. Scroll the Panel Network Configuration down to the Connection Type:
section (Figure8).
Figure 8. Panel Network Configuration - Connection Type
2. Select the LAN radio button for a LAN only system.
3. Enter the Device number in the LAN/Serial Device # field. This number
must match the Device Address field in the MPK Devices table (see
page 191 for more information).
4. Enter the IP address of the Primary host in the LAN Primary Host IP
field.
5. Enter the IP address of the Secondary (Redundant) host in the LAN
Secondary Host IP field.
6. Select the amount of time to wait for a response from the Control
module before timing out from the LAN Response Time-out drop-
down list. Grass Valley recommends using the default setting.
This setting is helpful if you have Contr
ol panels located a long distance
away from a Control module. The options are: 20mS, 40mS, 60mS, 80mS,
100mS, 250mS, 500mS, and 1S.
Note For control panels that are connected using a Serial connection, see the
appropriate pannel’s manual.