03 September 2009 K2 Storage Cabling Guide 55
K2 RAID for basic K2 SAN
K2 RAID for basic K2 SAN
These cabling instructions apply to the following:
Level 3 (NEC 1400) K2 RAID on a Level 3 basic (non-redundant) K2 SAN.
Primary Chassis
Expansion Chassis 1
Expansion Chassis 2
Set address to 0
Set address to 1
Set address to 0
Set address to 1
DL1 DL0
To K2 Media
Server 2
To Expansion
Chassis 3,
with address
set to 1
To Expansion
Chassis 4,
with address
set to 2
To K2 Media
Server 1
To control port
on GigE switch
The cable/address pattern, extended for
additional Expansion Chassis, is as follows:
Expansion Connect Set address
Chassis # to... to...
1 DL1 0
2 DL0 1
3 DL1 1
4 DL0 2
5 DL1 2
6 DL0 3
7 DL1 3
For more information, refer to the K2