55
Kula
Installation Manual
Mav Remote Specifications
Kula IP Mainframe Network/Serial/USB
Network 3x Ports - NET X1 to NET X3
10/100/1000 base T, Auto – MDX/MDXI on RJ45 connector.
2x Ports - NET X4 and NET X5
These are Network 10/100/1000 base T for each IP rear card control (RollCall).
‘A' card is NET X4
'B' card is NET X5
Serial Control 2 x RS-422 on RJ45.
USB 2x USB 3.0 - for external memory device or hard drive
USB outputs are 5 V DC, 0.9 A each
Note: All other connectors on the mainframe are the same as the standard
Kula SDI mainframe
Mav Remote
Connector Description
Video Output 1x Monitor Output
USB 2x USB 2 Connectors
Network 1x 10/100/1000 base T, Auto - MDX/MDXI on RJ45 connectors
Connections to
MAV modules
8x RJ45 connectors for Comms and 2x +12V 0.42A power supply
Connection to other MAV modules
NOT Ethernet, connections must be direct to MAV modules. Do Not use
network switches or hubs.
CAT5 or above cables - crossover cables are Not suitable.
Mav Remote Power Supplies
Power Supply Description
To the
Mav Remote
2x Fully independent external PSU modules with separate mains power feeds
via 2x 10A IEC leads.
Output from each PSU = 12V DC 100W via Kycon KPPX 4 Pin or Compatible
connectors to the Mav Remote.
2 supplied as standard per Mav Remote, One PSU provides Dual Redundancy.
Mav Remote External Mains Power Supply Requirements
Voltage 100V - 240V 50/60Hz
Power Less than 100Watts (per Mav Remote)

Table of Contents