GREE DC INVERTER HEAT PUMP CONDENSING UNIT
77
Removal of 4-way valve
NOTE: Before removing the 4-way valve, make sure refrigerant is fully discharged from the unit and power is cut off.
Step
Picture
Work instruction
4. Install the coil of 4-way
valve.
Tighten the screws of the
coil of 4-way valve with a
screwdriver.
Model: FLEXX36HP230V1AO
Removal of fan and motor
Note: Before removing the fan, make sure power is cut off.
Step
Picture
Work instruction
1. Remove the grill.
Use a screwdriver to
unscrew the two screws
on the upper left and lower
right corners.
2. Remove the fan.
Use a wrench to remove
the specialized nut and
gasket of the fan.
NOTE: Please keep the
nut and gasket safe after
removing them from the
fan.