Chart 6.9
Note:
1. “Power Rate” is used to set up power of battery. So different battery may have the different power,
customer need to check the max power of battery.
2. Time setting is 24-hour.If the end time is less than beginning time, it defaults to spanning days.
4. Under the MODE Change, you can see the setup options below after pressing Enter:
MODE Change
WorkMode
Sensor
WorkMode
Cable CT
WorkMode
Meter
SP-CT
Battery Type
WorkMode
Lithium
WorkMode
Lead-acid
Press enter key to
make sure
Press down key
to the next item
Press enter key
to make sure
Chart 6.10
The MODE change has two options what are sensor and battery type, sensor is cable CT (default), meter and
SP-CT(wireless RF transfer). In the battery type, you can choose lithium battery or lead-acid battery.
5. Under the ExportLimit, you can see the setup options below after pressing Enter:

Other manuals for Growatt SPH3600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH3600 and is the answer not in the manual?

Growatt SPH3600 Specifications

General IconGeneral
ModelSPH3600
TypeHybrid Inverter
Rated Power3600 W
Max PV Input Voltage550 V
Number of MPPTs2
Max Input Current per MPPT11 A
Nominal DC Voltage360 V
Nominal AC Power3600 W
Max AC Current16 A
Nominal AC Voltage230 V
AC Voltage Range180-280V
Nominal Grid Frequency50/60 Hz
THDi<3%
Max Efficiency97.5%
DC SwitchYes
Protection DegreeIP65
Battery Voltage Range42 V - 59 V
Communication InterfacesRS485, WiFi
Max AC Power3600W
Euro Efficiency97.0%
Operating Temperature Range-25°C to +60°C
CoolingNatural Convection