EasyManua.ls Logo

Grundfos ALPHA2 GO - Technical Data

Grundfos ALPHA2 GO
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12. Technical data
Supply voltage 1 × 220-240 V, ± 6%, 50/60 Hz
Minimum supply voltage
160 VAC (runs with reduced
performance)
Motor protection
The pump requires no external motor
protection.
Enclosure class
Indoor use only
IP44
IPX4D (only ALPHA2 K XX-75)
Temperature class
TF110 to EN 60335-2-51
TF95 to EN 60335-2-51 (only
ALPHA2 GO XX-90)
Reaction time - power on No specific requirements.
Reaction time - standby < 1 s
Reaction time - speed
change
< 1 s
Inrush current < 4 A
Standby power
consumption
2)
3)
< 0.7 W
Insulation class F
Relative humidity Max. 95 %
Max. outlet pressure 1.0 MPa (10 bar)
Surge robustness > 3 W (DWCM)
Radio frequency radiation
exposure
-6 dB CE/EN55014-1, CE/EN55014-2
Sound pressure level (LP) < 25 dB(A)
Pump housing Electrocoated cast iron
Connection type G 1, G 1 1/2, G 2
3)
Applicable for pumps that are stopped and connected to the power
supply. Only applicable for variants with the PWM functionality.
Product size
Max. flow rate (Q)
[m
3
/h]
Max. head (H)
[m]
XX-40 2.7 4.0
XX-60 3.5 6.0
XX-75 4.5 7.5
XX-90 4.8 9.0
Power usage (approximate)
Min.
Max.
XX-40 3 W 21 W
XX-60 3 W 37 W
XX-60 3 W 37 W
XX-75 3 W 75 W
XX-90 3 W 90 W
Liquid temperature
Max. ambient
temperature
55 °C
Max. ambient
temperature
70 °C
XX-40 2 to 110 °C 2 to 75 °C
XX-60 2 to 110 °C 2 to 75 °C
XX-75 -10 to +110 °C -10 to +75 °C
K XX-75 -20 to +110 °C -20 to +75 °C
XX-90 -10 to +95 °C -10 to +60 °C
Inlet pressure
Liquid temperature
[°C]
Min. inlet pressure
[bar]
75 0.05
95 0.5
110 1.08
Related information
2.5.1 Nameplate
23
English (GB)

Table of Contents