4.2 Changing the pump head position
CAUTION
Hot surface
Minor or moderate personal injury
‐ Position the pump so that persons cannot accidentally
come into contact with hot surfaces.
‐ The pump housing may be hot due to the pumped
liquid being scalding hot. Close the isolating valves on
both sides of the pump and wait for the pump housing
to cool down.
WARNING
Pressurised system
Minor or moderate personal injury
‐ Before disassembling the pump, drain the system
or close the isolating valves on both sides of the
pump. The pumped liquid may be under high
pressure.
To change the position of the pump head, do as follows:
1. Loosen and remove the four screws.
TM087974
2. Turn the pump head to the desired position.
TM087975
The control box can be turned in steps of 90°.
TM087893
ALPHA2 GO
TM088798
ALPHA2 GO K version
3. Insert and cross-tighten the screws (torque 5 Nm).
TM087976