3. Remove the screw (E).
E
TM084039
Model J
E
TM082866
Model K
4. Fit the module by aligning it with the three plastic holders (F)
and the connection plug (G). Press the module home, using
your fingers.
F
G
TM084040
Model J
F
G
TM082867
Model K
5. Fit and tighten the screw (E) to 1 ftlb (1.3 Nm).
6. Make the electrical connections to the module as described in
the instructions supplied with the module.
7. Connect the cable screens of the bus cables to ground via one
of the earth clamps (H).