10. Taking the product out of operation
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply and make sure that it
cannot be accidentally switched on.
The power supply must be switched off for at least five
minutes before you start working on the product.
WARNING
Back injury
Death or serious personal injury
Use lifting equipment and follow local regulations
when lifting the product.
The lifting eyes on the motor can be used for lifting the
pump as well.
11. Technical data
11.1 Technical data, three-phase motors
WARNING
Electric shock
Death or serious personal injury
Use the recommended fuse size.
Supply voltage
3 × 440-480 V -10 % / +10 %, 60 Hz, PE
3 × 200-240 V -10 % / +10 %, 60 Hz, PE
Check that the supply voltage and frequency correspond to the
values stated on the nameplate.
Recommended size of fuse
For recommended size of fuses see the tables below.
3 × 440-480 V, Model J
Motor size
[HP]
Recommended
[A]
Maximum
[A]
5 13 16
7 1/2 16 32
10 20 32
15 32 32
3 × 440-480 V, Model K
Motor size
[HP]
Recommended
[A]
Maximum
[A]
Fuse type
20 50 80 gG
25 60 80 gG
30 70 80 gG
3 × 200-240 V, Model J
Motor size
[HP]
Recommended
[A]
Maximum
[A]
3 13 35
5 25 35
7 1/2 32 35
For recommended size of fuses see the appendix
concerning installation in the USA and Canada.