EasyManua.ls Logo

Grundfos NBE Series - 6.1.2 Operating panels, HMI 300 and 301

Grundfos NBE Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H
Q
Max.
Min.
TM054895
6.1.1.3 Setting to maximum speed
The motor must not be in operating mode Stop.
Press and hold the Up button until the top light field is on and
starts flashing.
H
Q
TM054896
6.1.1.4 Setting to minimum speed
The motor must not be in operating mode Stop.
Press and hold the Down button until the bottom light field is on
and starts flashing.
H
Q
TM054897
6.1.1.5 Starting the pump
How you start the pump depends on how it was stopped.
Start the pump in one of the following ways:
- If the pump was stopped by pressing the Start/Stop button:
Start the pump by pressing the Start/Stop button.
- If the pump was stopped by pressing and holding the Down
button: Start the pump by pressing and holding the Up
button.
6.1.1.6
Stopping the pump
Stop the pump in one of the following ways:
- Press the Start/Stop button.
- Press and hold the Down button until all light fields are off.
- Use Grundfos GO.
- Use a digital input set to External stop.
6.1.1.7
Resetting alarms and warnings in products with the HMI
200 or 201 operating panel
You can reset a fault indication in one of the following ways:
- Briefly press the Up or Down button.
This is not possible if the buttons have been locked.
This does not change the setting of the motor.
- Switch off the power supply until the indicator lights are off.
- Switch the external start and stop input off, and then on
again.
- Use Grundfos GO.
- Use the digital input if you have set it to Alarm resetting.