7.6 Initial startup
For description of control elements, navigation and initial display,
see section 7.1 Control elements, 7.3 Navigation and 7.2 Initial
display.
1. Open the dilution water supply.
2. Switch on the power supply.
3. Select the language.
4. Enter the service code (see section 7.4 Access codes).
Fig. 33 Initial display
7.7 Language
1. "main menu > commissioning > language"
2. Select the "language".
7.8 Date/time
Setting the date
1. "main menu > commissioning > date/time > date"
2. Set the date.
Setting the time
1. "main menu > commissioning > date/time > time"
2. Set the time.
7.9 Batch tank
This menu also affects the production mode, see section
5.4.1 Operation modes.
1. "main menu > commissioning > batch tank"
Internal batch tank
1. "internal"
X = 1...20: The number of batches to produce.
X = 0: Continuous production of batches
External batch tank
1. "external"
The production is running until the external batch tank is filled.
7.10 Display contrast
Adjust the display contrast in "main menu > commissioning >
display contrast"
7.11 Measuring setup
7.11.1 Measuring cell
"main menu > commissioning > measurement > on > measuring
cell"
The parameters in the display depend on the selected measuring
cell.
AQC-D1/ -D11
Temperature measurement
1. Select your setting.
Temperature compensation
2. Select your setting.
Monitoring the cleaning motor
3. Select your setting.
Parameters
4. Select the measuring parameter(s).
AQC-D6
When selecting measuring cell AQC-D6, the measuring
parameter is automatically set to ClO
2
.
Key Menu Submenu 1 Submenu 2 Submenu 3
[Cal] calibration
ClO2
cal. meas. value
cal. result
cal. cycle
on
off
pH
cal. meas. value
cal. result
cal. cycle
on
off
ORP
cal. meas. value
cal. result
cal. cycle
on
off
[Man] manually dosing
TM03 6905 4506
batch tank
internal
external
no. of batches
X
0 = continuous
1 2
3
45
8
6
24.5 °C
0.23 mg/l
pH 7.36
prod. terminated
temperature
on
off
temp. comp.
on
off
cleaning motor
monitoring on
monitoring off
measurement
ClO2
ClO2 + pH
ClO2 + ORP