15.3 Maintenance kits 15.4 Accessories
Prior to installation, the operator must purchase the following
accessories according to the product numbers in the OCD-162
data booklet.
OCD-162-5 Order no.
Dosing pump DDE 6-10 (230 V / 115 V) 97751181
Dosing pump DDA 7.5-16 (230 V / 115 V) 97751181
Solenoid valve (230 V / 115 V) 95702990
O-rings for reaction tank and internal batch tank 95702992
Activated carbon filter and volume compensation
bag
95702994
Complete kit with dosing pump DDA 7.5-16 98153636
Complete kit without dosing pump 98153651
OCD-162-10 Order no.
Dosing pump DDE 6-10 (230 V / 115 V) 97751181
Dosing pump DDA 7.5-16 (230 V / 115 V) 97751181
Solenoid valve (230 V / 115 V) 95702990
O-rings for unit of reaction tank and internal batch
tank
95702992
2 activated carbon filters and 2 volume
compensation bags
95705995
Complete kit with dosing pump DDA 7.5-16 98153962
Complete kit without dosing pump 98153966
OCD-162-30 Order no.
Dosing pump DDE 15-4 (230 V / 115 V) 97751217
Dosing pump DDI (230 V / 115 V) 95715695
Dosing pump DMX (230 V) 95715694
Solenoid valve (230 V / 115 V) 95717912
Pair of Isolating valves
(0.8 bar, installed in the suction lance)
98165354
O-rings for reaction tank 95717913
Adsorption filter and volume compensation bag 95717914
Complete kit with dosing pump DMX 98162637
Complete kit with dosing pump DDI 98162644
Complete kit without dosing pump 98162647
OCD-162-60 Order no.
Dosing pump DMX (230 V / 115 V) 95715693
Dosing pump DDI (230 V / 115 V) 95715695
Solenoid valve (230 V / 115 V) 95717912
Pair of isolating valves
(0.8 bar, installed in the suction lance)
98165354
O-rings for reaction tank 95717913
Adsorption filter and 2 volume compensation bags 95717918
Complete kit with dosing pump DMX (230 V) 95717919
Complete kit with dosing pump DDI 95717920
Complete kit without dosing pump 95717921
Accessories
Available
from
Grundfos
Protective clothing ●
Plastic buckets -
Sodium thiosulfate ●
Container with NaClO
2
(diluted concentration of
7.5 % by weight in accordance with EN 938)
-
Container with HCl (diluted concentration of 9 %
by weight in accordance with EN 939)
-
Two collecting trays for the chemical containers ●
Inductive or ultrasonic water meter, if necessary ●
Water meter connection cable, if necessary ●
For dilution water line
In case no bypass mixing module with dilution
water connection was ordered.
• Tapping sleeve -
• Extraction device ●
• Connection for dilution water hose ●
• Sample-water filter; in case of insufficient water
quality
●
For main water line
• Tapping sleeve for injection unit -
• Two tapping sleeves for extension module, if
necessary
-
• Tapping sleeve for sample-water extraction -
Hoses
• Hose between dilution water extraction device
and solenoid valve
●
• Dosing line between dosing pump and injection
unit
●
Measuring cell hoses
• Hose between measuring cell and sample-
water extraction device
●
• Hose between measuring cell and drain ●
For bypass mixing module, if installed
• Hose between bypass mixing module and main
water line and hose back to bypass mixing
module
●
• Dosing line between dosing pump and injection
unit in bypass mixing module
●
For measuring module, if installed
• Hose between measuring module and main
water line and hose back to measuring module
●
• Protective pipe for dosing hose -
• Main switch -
Cables
• System power supply cable -
• Power cable for measuring module or bypass
mixing module, if necessary
-