EasyManuals Logo

Grundfos SMART Digital XL DDA 60-10 User Manual

Grundfos SMART Digital XL DDA 60-10
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
English (GB)
49
* Depending on setting
Disch. valve leak
(Alarm)
Leaky/dirty outlet valve. Dosing
medium flows back from the outlet
line into the dosing head and
moves the motor.
Inlet pressure too high. Dosing
medium flows from the inlet line
into the dosing head and moves
the motor.
Replace valve if necessary. See section
8.4 Perform service.
Install screen in inlet line.
Reduce inlet pressure. Observe section
4.1 Technical data.
Cavitation
(Alarm)
Blocked / constricted / squeezed
inlet line
Blocked/constricted inlet valve
Suction lift too high
Viscosity too high
Cavitation moves the motor
Enable "SlowMode". See section
7.6
SlowMode
.
Reduce suction lift.
Increase inlet line diameter.
Check inlet line and open isolating valve if
necessary.
Overheating
(Alarm)
Motor is overheated Reduce ambient temperature.
Stop pump until motor cools down.
Service now
(Warning)
Time interval for service expired Perform service. See section 8.4 Perform
service.
Display in the
"Alarm" menu
Possible cause Possible remedy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SMART Digital XL DDA 60-10 and is the answer not in the manual?

Grundfos SMART Digital XL DDA 60-10 Specifications

General IconGeneral
Max Flow Rate60 l/h
Max Pressure10 bar
Control TypeDigital
Protection ClassIP65
Power Supply50/60 Hz
Turn-down ratio1:3000
ApprovalsCE
Operating Temperature0°C to +45°C

Related product manuals