DA98D User Manual
7
The servo driver does not have any protection within its own structure, so it must be
installed within the electric cabinet with good protection and prevented from contact of
corrosive and combustible air. Conductive matters, metal dust, oil fog or liquid shall be
prevented from entering inside.
(2) Temperature and Humidity
The environmental temperature shall be kept between 0 and 50 , while temperature for ℃℃
long-term safety operation shall be kept below 45 . Good conditions for heat radiating ℃
shall be guaranteed.
(3) Vibration and Impact
When installing the drive unit, vibration shall be avoided. Vibration reduction measures shall
be taken to control the vibration below 0.5G (4.9m/S2).
2) Installment Methods
(1) Ways of Installment
The user can adopt the ways of installment by back panel or panel. The installment shall form
an upward right angle with the installment plane. Fig. 2.1 is a schematic diagram for
installment by back panel and Fig. 2.2 is a schematic diagram for installment by panel.