ADVANCED MEASUREMENT
103
Show Math result
Background
The Math page in MathDisp allows you to
view mathematical calculations for several
parameters.
Operation
Press the F3 (Math) key to show
the mathematical analysis instantly as below.
View Data
-012.1597
Indicates the calculated dB value
Measure:
+000.7479mV
Indicates the originally measured
m Voltage value
Ref Ω: 0002 Ω
Indicates the defined reference
resistance value
Ref Voltage:
+003.0330mV
Indicates the measured reference
voltage value
Ref dBm:
-023.3727
Indicates the measured reference
dBm value
Deactivate dB
measurement
To cancel the dB measurement, press the F1
(Function) key followed by clicking F1 (OFF)
to deactivate or simply activate another
measurement.