GPP Series User Manual
128
Example
OUT1
Turns on the output
Command
:OUTPut[1|2|3|4]:OVP:STATe <b>
Function
Turns OVP protection on/off
Description
<b>
0/OFF:Turns OVP off.
1/ON:Turns OVP on.
Example
:OUTPut2:OVP:STATe ON
Turn on OVP on CH2.
Command
:OUTPut[1|2|3|4]:OVP:STATe?
Function
Queries the status of the OVP function.
Example
:OUTPut2:OVP:STATe?
Returns the status of the OVP function on CH2.
Command
:OUTPut[1|2|3|4]:OVP:TRIGer?
Function
Query whether the OVP protection function has
been triggered
Example
:OUTPut2:OVP:TRIGer?
Return whether the OVP protection function of
channel 2 has been triggered
Command
:OUTPut[1|2|3|4]:OVP <value>
Function
Sets the OVP level.
Description
<value>
Refer to the specification sheet on
page 200 for value
Example
:OUTPut2:OVP 10.5
Sets the OVP voltage to 10.5V for CH2.