GPP Series User Manual
158
Enable or disable sequence function.
To enable sequence will change state of channel
output, make sure the changed output state will
Not impact the device connected with power before
enabling. Sequence output is activated only when
both sequence and channel output are enabled. To
modify parameter is Not available when sequence
is being enabled. For multi-channel model, change
the active channel and set parameter of selected
channel. It is Not allowed to enable sequence and
delay simultaneously.
:SEQUence2:STATe ON
Enable sequence output for CH2
Queries the state of sequence output .
:SEQUence2:STATe?
Queries the CH2 state of sequence output. Returns
to ON or OFF.
:SEQUence : SYNChronize {ON|OFF}
When both CH1 and CH2 are sequence on, turn on
or off the sequence synchronization between them.
: SEQUence : SYNChronize ON
turn on the sequence synchronization of CH1 and
CH2.
:SEQUence[1|2]:TEMPlet:CONSTruct
Sends the command. Instrument builds, based on
the actively selected templet and set the sequence
parameter.