EasyManuals Logo

GW Instek GPP-2323 User Manual

GW Instek GPP-2323
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
REMOTE CONTROL
175
Example
STATUS?
Command
:STATus:PRESet
Function
Clears the operation event enable registers, the
measurement event enable registers and the
questionable event register, The unit will then
return to the default settings status.
Example
:STATus:PRESet
Command
:STATus:OPERation[:EVENt]?
Function
Read the operation event register.
Example
:STATus:OPERation?
Reads the operation event register.
Command
:STATus:OPERation:CONDition?
Function
Read the operation condition status register.
Example
:STATus:OPERation:CONDition?
Read the contents of the operation condition
status register.
Command
:STATus:OPERation:ENABle <NRf>
Function
Programs the operation enable status register.
Description
<NRf>
8: CL (Current enable bit).
16: CLT (Current limit tripped enable
bit).
64: PSS (Power supply shutdown
enable bit).
Example
:STATus:OPERation:ENABle 64
Enable the power supply shutdown bit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-2323 and is the answer not in the manual?

GW Instek GPP-2323 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-2323
CategoryPower Supply
LanguageEnglish

Related product manuals