REMOTE CONTROL
147
Example
:MONItor2:CURRent:CONDition <C,AND
Sets the CH2current monitor condition for monitor
as <current, and the logical pattern as “and”.
Command
:MONItor[1|2|3|4]:CURRent:CONDition?
Function
Queries the current monitor condition for monitor
(active channel).
Example
:MONItor2:CURRent:CONDition?
Queries the CH2 current monitor condition for
monitor. Returns to the current monitor condition
and logical pattern.
Command
:MONItor[1|2|3|4]:CURRent[:VALue]{<value>|
MINimum|MAXimum}
Function
Queries the current monitor value for monitor
(active channel).
Description
<value> The range available is from 0 to the
maximum current value of active channel.
Example
:MONItor2:CURRent 2
Sets CH2current monitor value for monitor as 2A.
Command
:MONItor[1|2|3|4]:CURRent[:VALue]?
Function
Queries the current monitor value for current
monitor (active channel).
Example
: MONItor2: CURRent?
Queries the CH2 current monitor value for current
monitor. Returns to the current monitor value of
current monitor.
Command
:MONItor[1|2|3|4]:POWEr:CONDition
{<P|>P||=P|NONE}