PSU Series Programming Manual
108
Example 1
:SYST:BEEP 10
**after a 2 second wait**
:SYST:BEEP?
>8
The first command turns the beeper on for 10
seconds. After 2 seconds the SYST:BEEP? Query
returns the remaining beeper time (8 seconds).
Example 2
:SYST:BEEP? MAX
>3600
Returns the maximum settable beeper time in
seconds.
:SYSTem:CONFigure:BEEPer[:STATe]
Set
Query
Description
Sets or queries the buzzer state on/off.
Syntax
Query Syntax
:SYSTem:CONFigure:BEEPer[:STATe]
{<bool>|OFF|ON}
:SYSTem:CONFigure:BEEPer[:STATe]?
Parameter
OFF | 0
Turns the buzzer off.
ON | 1
Turns the buzzer on.
Return parameter
<bool>
Returns the buzzer status.
:SYSTem:CONFigure:BLEeder[:STATe]
Set
Query
Description
Sets or queries the status of the bleeder resistor.
Syntax
Query Syntax
:SYSTem:CONFigure:BLEeder[:STATe]
{<NR1>|OFF|ON|AUTO}
:SYSTem:CONFigure:BLEeder[:STATe]?
Parameter
OFF | 0
Turns the bleeder resistor off.
ON | 1
Turns the bleeder resistor on.
AUTO | 2
Turn the AUTO mode on.
Return parameter
<NR1>
Returns bleeder resistor status.