optional settings: administrator options
file: n:\article\cos14310m5-v1_08hpc-en\20150130_cos14310m5-v1.08hpc-en_instructions_for_use_h-p-cosmos_treadmill.doc
© 2015 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 30.01.2015 printed 30.01.2015 page: 157 of 216
Standard settings of administrator options
Reset of error messages E20, E21,
E30, E31, E32, E41, E50 and E51
0 = h/p/cosmos (Standard)
1 = JAEGER / VIASYS / Cardinal
Health / CareFusion
2 = Ergo-Fit (1997-98)
3 = Proxomed / Kardiomed
4 = KISTLER Gaitway
6 = COSMED
9 = SCHILLER
Selection of device type:
see list of running machines types
Maximum speed for reverse belt
rotation
depending on the device type
in OP03
depending on the device type
in OP03
Max. acceleration time in seconds
depending on the device type
in OP03
Heart rate display interval
Display test for all displays
Enter the serial number of the
device
Activating and deactivating speed
measurement
depending on the device type
in OP03
0 = without speed measurement
1 = with speed measurement
Setting of allowance for speed signal
comparison
This value does not reflect the
speed accuracy of the running
belt.
6 = 6 % deviation allowed
8 = 8 % deviation allowed
10 = 10 % deviation allowed
Maximum acceleration time for
RS232
Activating and deactivating heart
rate measurement
0 = HF measurement deactivated
1 = HF measurement activated,
HFU1 + RE06REC
2 = HF measurement activated,
HFUi;
auto = autom. detection
Distance between rungs (only for
ladder ergometer)
Distance between rungs in 0.1 cm
(depending on the device
type, OP 03)
100 km (ladder ergometer)