190
Parameters
controller_id: Specifies the ID of the storage controller.
mode: Specifies the operating mode of a storage controller. Options include:
2: Specifies the HBA mode.
3: Specifies the RAID mode.
5: Specifies the Mixed mode.
Examples
# Set the storage controller mode to RAID.
[root@localhost home]# arcconf setcontrollermode 1 0
Controllers found: 1
Changing the mode to RAID will remove access to physical drives from the operating system.
Do you want to change the controller mode setting for the configuration?
Press y, then ENTER to continue or press ENTER to abort: y
Command completed successfully.
# View the storage controller mode, that is, Controller Model parameters.
[root@localhost home]# arcconf getconfig 1 ad
Controllers found: 1
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller Status : Optimal
Controller Mode : RAID (Hide RAW)
Channel description : SCSI
Controller Model : UN RAID P460-B2
Vendor ID : 0x9005
Device ID : 0x028F
Subsystem Vendor ID : 0x193D
Subsystem Device ID : 0xC461
Controller Serial Number : Unknown
Controller World Wide Name : 598F181BA1DBB000
Physical Slot : 19
Temperature : 44 C/ 111 F (Normal)
Host bus type : PCIe 3.0
Host bus speed : 7880 MBps
Host bus link width : 8 bit(s)/link(s)
PCI Address (Domain:Bus:Device:Function) : 0:17:0:0
Number of Ports : 2
Internal Port Count : 2
External Port Count : 0
Defunct disk drive count : 0
NCQ status : Enabled
Queue Depth : Automatic
Monitor and Performance Delay : 60 minutes
Elevator Sort : Enabled