EasyManuals Logo

H3C UniServer R4300 G6 User Manual

H3C UniServer R4300 G6
542 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #196 background imageLoading...
Page #196 background image
121
Device Number = 0
Function Number = 0
Physical Drives = 2
PD LIST :
=======
-------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-------------------------------------------------------------------------------
2:8 39 UGood - 5.457 TB SATA HDD N N 512B ST6000NM0115-1YZ110 U -
2:23 61 UGood - 1.818 TB SATA HDD N N 512B ST2000NM0125-1YZ104 U -
-------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported
Switching the storage controller mode
Perform this task to switch the storage controller mode.
Syntax
storcli64 /ccontroller_id set personality =mode
Default
A storage controller operates in RAID mode.
Parameters
controller_id: Specifies the ID of a storage controller. If only one storage controller exists, the
ID is 0 by default. If multiple storage controllers exist, use the
storcli64 /call show command
to view the controller ID.
mode: Specifies the controller mode. Options include:
•
raid: Specifies the RAID mode.
•
jbod: Specifies the JBOD mode.
Usage guidelines
•
Before switching the controller mode to JBOD, make sure the storage controller is using the
most recent version. Lower versions may not support the JBOD mode.
•
Before using this command, make sure all drives managed by the storage controller are in
Unconfigured Good state.
•
For the configuration to take effect, you must restart the operating system after executing the
command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R4300 G6 and is the answer not in the manual?

H3C UniServer R4300 G6 Specifications

General IconGeneral
BrandH3C
ModelUniServer R4300 G6
CategoryServer
LanguageEnglish

Related product manuals