6
Figure 7 Storage controller configuration screen
2. Perform the following tasks:
a. Select a target logical drive and set its state to Enabled.
b. Set the Are you sure you want to delete the selected virtual Disk? field to Yes.
c. Select Accept and press Enter.
Figure 8 Deleting a RAID array
Rebuilding a RAID array
This feature rebuilds the RAID array for drive replacement when a member drive in RAID 1 failed.
To rebuild a RAID array:
1. Access the storage controller configuration screen, select Rebuild RAID Configuration, and
press Enter.