200
Command completed successfully.
Set the drive initialization or uninitialization state
Perform this task to set the drive initialization or uninitialization state.
Syntax
arcconf task start controller_id device channel_id device_id type
Parameters
controller_id: Specifies the ID of the storage controller.
channel_id: Specifies the channel ID of the drive. To obtain the channel ID, use the arcconf
getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output
represent the channel and ID.
device_id: Specifies the drive ID. To obtain the drive ID, use the arcconf getconfig
controller_id pd command. The Reported Channel and Device (T:L) fields in the output
represent the channel and ID.
type: Specifies the task type. Options include initialize and uninitialize.
Usage guidelines
If you specify all as the channel_id device_id, the command initializes or uninitializes all
drives managed by the storage controller.
Examples
# Set the drive with device ID 9 for storage controller 1 to initialized state.
[root@localhost ~]# arcconf task start 1 device 0 9 initialize
Controllers found: 1
Initializing Channel 0, Device 9 will erase its metadata, the section
where all the logical device definition data is stored
Are you sure you want to continue?
Press y, then ENTER to continue or press ENTER to abort: y
Initializing Channel 0, Device 9.
Command completed successfully.
Configure and delete hot spare drives for logical drives
Perform this task to configure hot spare drives for logical drives.
Syntax
To create a hot spare drive:
arcconf setstate controller_id device channel_id slot_id hsp array
array_id sparetype type
To delete a hot spare drive:
arcconf setstate controller_id device channel_id slot_id rdy

Table of Contents