Replacement Parts & Accessories
REPLACEMENT PARTS
Description Cat. No.
StablCal Calibration Set for 2100P, Sealed Vials:
<0.1 NTU, 20 NTU, 100 NTU, and 800 NTU ...................... 26594-05
AA Batteries, 4/pkg ..................................................................19380-04
Battery Door .............................................................................46005-00
Carrying Case ...........................................................................46506-00
Gelex
®
Standards, set (includes standards and 3 sample cells) 24641-05
Instrument Manual....................................................................46500-88
Lamp Assembly, with leads ......................................................46539-00
Mounting Feet, 4/pkg................................................................41093-00
Oiling Cloth ..............................................................................47076-00
Sample Cells, 1 inch, with cap, 6/pkg....................................... 24347-06
Silicone Oil, 15 mL..................................................................... 1269-36
OPTIONAL ACCESSORIES AND REAGENTS
Deionized Water, 3.78 L ...............................................................272-17
Bath, Ultrasonic, 2.8 L (0.75-gal), w/heater .............................24895-00
Battery Charger, 120 V .............................................................46479-00
Battery Charger, 230 V .............................................................46479-01
Battery Eliminator, 120 V.........................................................46079-00
Battery Eliminator, 230 V.........................................................46080-00
Filter, 0.2 micron, 10/pkg .........................................................23238-10
Formazin, 4000 NTU, 500 mL ................................................... 2461-49
Formazin, 4000 NTU,100 mL .................................................... 2461-42
Hexamethylenetetramine, 100 g ................................................. 1878-26
Hexamethylenetetramine, 500 g ................................................. 1878-34
Hydrazine Sulfate, 20 g ................................................................742-46
Hydrazine Sulfate, 100 g ..............................................................742-26
NiCad Rechargeable Battery (4 required) ................................ 16077-00
Pipet, serologic, 1.00 mL..............................................................532-35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hach 2100P and is the answer not in the manual?

Hach 2100P Specifications

General IconGeneral
Range0 to 1000 NTU
Light SourceTungsten filament lamp
DetectorSilicon photodiode
Operating Temperature0 to 50 °C (32 to 122 °F)
Power4 AA alkaline batteries
Resolution0.01 NTU
Measurement PrincipleNephelometric
DisplayLCD