16
Common fault and solution
Indicator State
“-”show pause
Fault indication Solution
Red Green Without load
Check if these happen:the
connection of battery and charger is
loose, the battery reversed, or the
battery voltage is too low.
Red-Green-Red
---
Over voltage or over
current
If the error opens again after restart
,return it to factory repair.
Red Green Red
Green - -
The ambient
temperature is too high
or too low
Please check if the ambient
temperature is too high and if
ventilation is good and the position
of battery temperature sensor.
GreenRed---- Chargeroverheating
Please check whether ambient
temperature is too high and if
ventilation is good.
Red Green - - - - Output Under- Voltage Please return it to the factory.
Red Green Red
Green Red -
Input AC abnormality
Please check the input voltage and
the plug poor contact.
Green Red
Green----
Anyone of the
above-mentioned faults
repeats five times, then
it appears.
Re-up electricity, match the indicator
state to the above-mentioned faults
then get the corresponding solution.
Notes: ”:The charger product with communication needs to check the communication
connection line.
4 Battery changed and installation
Remove the battery panel and find 2 batteries.
The stacker must be parked on level
ground. To prevent short circuits,
batteries with exposed terminals or
connectors must be covered with a
rubber mat. Place the battery
connector or the battery cable in
such a way that they will not get
caught on the stacker when the
battery is removed.

Table of Contents