5 - Operation
91
3. Press to key in the volume in the MainTank after AutoFill has
ended.
Example when having a 7000 litre MainTank:
÷
NOTE! Even when filling to same amount as at last AutoFill,
you must press the tank content and accept the value.
μ
ATTENTION! Do not fill up to more than nominal tank
contents.
4. Go to the sprayer and press the button.
5. When an amount of water is filled, press button to close the
FastFiller valve, which pauses the filling.
6. Set the Suction and Pressure SmartValves for use of TurboFiller on
the blue and green buttons at the FluidBox.
Actual tank contents: 755 litre
You want to add: 6300 litre
In this menu you key in = 6955 litre
Daily settings
litre
Keyin volume in main tank when
filled