HFS6801+ Installation and Operation Manual 19
Chapter 2: Installation
11. Choose the upgrade ZIP file on a local or network drive.
The selected file’s path name is displayed in the edit box to the left
of the Browse… button.
The extraction process on the ZIP file is handled as part of the
upgrade process. You do not need to extract the files yourself.
You can view the contents of the ZIP file by clicking Package
Info.
12. Press Submit Transfer...
A dialog box opens, requesting confirmation that you want to
proceed with the request. If you have multiple devices selected,
multiple transfer tasks are submitted—one per device.
The transfer now progresses. You may minimize the Software
Upgrade window, continue with other tasks, or switch to the
Progress tab to view the status of the transfers.
Closing the Software Upgrade window does not effect any of
the transfer processes that may be running in the background.
If you try to log off or exit the CCS software while a transfer is
underway, a notification window will alert you that processes
are still active and will ask if you want to terminate these
processes.
13. Click on the Log tab and look at the Progress column to ensure that
all files have correctly updated.
14. When the update is complete, reboot the module by manually
pulling it out and then pushing it back into its slot in the frame.
You cannot click Reboot Device to reboot 6800+ modules that
must be upgraded in Boot Loader mode.
Your upgrade procedure is complete.
If for some reason the upgrade fails, the module may not respond to
controls and will appear to be non-functional. In that event, follow the
procedures described in “Correcting a Failed Upgrading Procedure” on
page 20.