EasyManuals Logo

Hawk Gladiator User Manual

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
24
25
Sultan 234 Series
Admittance Smart Switch Series
Manual
Rev 1.2, June 2008
QuickSet
Advanced
To Calibrate
UnLock
0
Sensor Value
0.0%
Advanced Menu
covers less commonly
used or advanced
parameters.
CAL
CAL
Press
Press
QuickSet Menu
covers all parameters
required for standard
setups.
On first start up there is
no security code protection.
Press
CAL
Press
To QuickSet
flow chart
CAL
Press
To Advanced
flow chart
Normal Running Display
to return to normal operation
RUN
Press
FLOW CHART
SOFTWARE TREE
SOFTWARE VERSION 7.14
See page 26
See page 27

Other manuals for Hawk Gladiator

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hawk Gladiator and is the answer not in the manual?

Hawk Gladiator Specifications

Power IconPower
operating voltage12-30VDC, 90-260VAC, 36-60VDC
power consumption<0.8W @ 24VDC, <5VA @ 240Vac, <3VA @ 115Vac
Operating Environment IconOperating Environment
maximum operating pressure2 BAR
operating temperature for remote electronics-40°C (-40°F) to 80°C (176°F)
operating temperature for remote sensors-20°C (-4°F) to 80°C (176°F)
enclosure sealing for remote electronicsIP67 (NEMA 4x)
enclosure sealing for remote sensorsIP68
Weight and Dimensions IconWeight and Dimensions
transducer to amplifier separationUp to 500m (1640ft)
typical weight for 15kHz transducer8 kg
typical weight for remote amplifier1 kg

Related product manuals